Use of electrical insulating shoes

Leave a message

 

Electrical insulation shoes is a safety shoes series, generally divided into low-voltage insulation, 6KV insulation or 10KV above the high voltage insulation.As a kind of safety protective equipment worn by electricians in power distribution operation, proper use is an important prerequisite for safety assurance.

(1) if there is a danger of electric shock, electric insulating shoes should be worn. Electrical insulating shoes should be worn in a suitable working environment. They should be used as auxiliary safety appliances and labor protection supplies when working.

(2) note that electrical insulation shoes cannot guarantee 100% protection from electric shock, and additional testing is necessary to avoid this danger.Such tests, like the additional tests mentioned below, should be part of the routine risk assessment procedure.

(3) during the service life, the electrical performance of insulating shoes shall meet the requirements at any time.

(4) during use, insulated shoes may be damaged by Nick, cutting, abrasion or chemical pollution. Regular inspection should be conducted. The damaged shoes can no longer be used as insulated shoes.

(5) it is forbidden to wear in places that pollute sole materials, such as chemicals, etc., which will affect the electrical performance of shoes when entering such dangerous areas.

(6) when wearing, it is suggested that the user should establish a suitable means of checking and testing the electrical insulation performance of the shoes.

(7) the working environment should keep the upper dry when wearing this product.

(8) the voltage resistance and leakage current value of the electric insulating shoes that have been prophylactic tested shall meet the standard requirements, and the validity period of each prophylactic test result shall not exceed 6 months.

(9) it is strictly prohibited to contact with sharp instruments, high temperature, acid, alkali or other corrosive substances. During storage, it shall be stored in a dry and ventilated warehouse to prevent mildew and pile up more than 0.2m away from the floor and walls.

(10) the storage period is 24 months, and products over 24 months shall be tested for preventive electrical performance one by one, and then they can be used as insulating shoes after passing the inspection.

When people is in to the use of electrician insulation shoe, must understand the safe limits of this shoe in detail, and the place when using taboo a few respects, such ability accomplish oneself safety to assure better.

 